Category Archives: Ear Hear

Perceptual Discrimination of Speaking Style Under Cochlear Implant Simulation.

Related Articles

Perceptual Discrimination of Speaking Style Under Cochlear Implant Simulation.

Ear Hear. 2018 May 08;:

Authors: Tamati TN, Janse E, Başkent D

Abstract
OBJECTIVES: Real-life, adverse listening conditions involve a great deal of speech variability, including variability in speaking style. Depending on the speaking context, talkers may use a more casual, reduced speaking style or a more formal, careful speaking style. Attending to fine-grained acoustic-phonetic details characterizing different speaking styles facilitates the perception of the speaking style used by the talker. These acoustic-phonetic cues are poorly encoded in cochlear implants (CIs), potentially rendering the discrimination of speaking style difficult. As a first step to characterizing CI perception of real-life speech forms, the present study investigated the perception of different speaking styles in normal-hearing (NH) listeners with and without CI simulation.
DESIGN: The discrimination of three speaking styles (conversational reduced speech, speech from retold stories, and carefully read speech) was assessed using a speaking style discrimination task in two experiments. NH listeners classified sentence-length utterances, produced in one of the three styles, as either formal (careful) or informal (conversational). Utterances were presented with unmodified speaking rates in experiment 1 (31 NH, young adult Dutch speakers) and with modified speaking rates set to the average rate across all utterances in experiment 2 (28 NH, young adult Dutch speakers). In both experiments, acoustic noise-vocoder simulations of CIs were used to produce 12-channel (CI-12) and 4-channel (CI-4) vocoder simulation conditions, in addition to a no-simulation condition without CI simulation.
RESULTS: In both experiments 1 and 2, NH listeners were able to reliably discriminate the speaking styles without CI simulation. However, this ability was reduced under CI simulation. In experiment 1, participants showed poor discrimination of speaking styles under CI simulation. Listeners used speaking rate as a cue to make their judgements, even though it was not a reliable cue to speaking style in the study materials. In experiment 2, without differences in speaking rate among speaking styles, listeners showed better discrimination of speaking styles under CI simulation, using additional cues to complete the task.
CONCLUSIONS: The findings from the present study demonstrate that perceiving differences in three speaking styles under CI simulation is a difficult task because some important cues to speaking style are not fully available in these conditions. While some cues like speaking rate are available, this information alone may not always be a reliable indicator of a particular speaking style. Some other reliable speaking styles cues, such as degraded acoustic-phonetic information and variability in speaking rate within an utterance, may be available but less salient. However, as in experiment 2, listeners’ perception of speaking styles may be modified if they are constrained or trained to use these additional cues, which were more reliable in the context of the present study. Taken together, these results suggest that dealing with speech variability in real-life listening conditions may be a challenge for CI users.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

PMID: 29742545 [PubMed – as supplied by publisher]

Continue reading

Posted in Ear Hear | Tagged , | Comments Off on Perceptual Discrimination of Speaking Style Under Cochlear Implant Simulation.

The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?

The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?

Ear Hear. 2015 Mar 27;

Authors: Boyen K, Başkent D, van Dijk P

Abstract
OBJECTIVES: Animals with induced tinnitus showed difficulties in detecting silent gaps in sounds, suggesting that the tinnitus percept may be filling the gap. The main purpose of this study was to evaluate the applicability of this approach to detect tinnitus in human patients. The authors first hypothesized that gap detection would be impaired in patients with tinnitus, and second, that gap detection would be more impaired at frequencies close to the tinnitus frequency of the patient.
DESIGN: Twenty-two adults with bilateral tinnitus, 20 age-matched and hearing loss-matched subjects without tinnitus, and 10 young normal-hearing subjects participated in the study. To determine the characteristics of the tinnitus, subjects matched an external sound to their perceived tinnitus in pitch and loudness. To determine the minimum detectable gap, the gap threshold, an adaptive psychoacoustic test was performed three times by each subject. In this gap detection test, four different stimuli, with various frequencies and bandwidths, were presented at three intensity levels each.
RESULTS: Similar to previous reports of gap detection, increasing sensation level yielded shorter gap thresholds for all stimuli in all groups. Interestingly, the tinnitus group did not display elevated gap thresholds in any of the four stimuli. Moreover, visual inspection of the data revealed no relation between gap detection performance and perceived tinnitus pitch.
CONCLUSIONS: These findings show that tinnitus in humans has no effect on the ability to detect gaps in auditory stimuli. Thus, the testing procedure in its present form is not suitable for clinical detection of tinnitus in humans.

PMID: 25822647 [PubMed – as supplied by publisher]

Continue reading

Posted in Ear Hear | Comments Off on The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?

A Retrospective Multicenter Study Comparing Speech Perception Outcomes for Bilateral Implantation and Bimodal Rehabilitation.

A Retrospective Multicenter Study Comparing Speech Perception Outcomes for Bilateral Implantation and Bimodal Rehabilitation.

Ear Hear. 2015 Feb 18;

Authors: Blamey PJ, Maat B, Başkent D, Mawman D, Burke E, Dillier N, Beynon A, Kleine-Punte A, Govaerts PJ, Skarzynski PH, Huber AM, Sterkers-Artières F, Van de Heyning P, O’Leary S, Fraysse B, Green K, Sterkers O, Venail F, Skarzynski H, Vincent C, Truy E, Dowell R, Bergeron F, Lazard DS

Abstract
OBJECTIVES:: To compare speech perception outcomes between bilateral implantation (cochlear implants [CIs]) and bimodal rehabilitation (one CI on one side plus one hearing aid [HA] on the other side) and to explore the clinical factors that may cause asymmetric performances in speech intelligibility between the two ears in case of bilateral implantation.
DESIGN:: Retrospective data from 2247 patients implanted since 2003 in 15 international centers were collected. Intelligibility scores, measured in quiet and in noise, were converted into percentile ranks to remove differences between centers. The influence of the listening mode among three independent groups, one CI alone (n = 1572), bimodal listening (CI/HA, n = 589), and bilateral CIs (CI/CI, n = 86), was compared in an analysis taking into account the influence of other factors such as duration of profound hearing loss, age, etiology, and duration of CI experience. No within-subject comparison (i.e., monitoring outcome modifications in CI/HA subjects becoming CI/CI) was possible from this dataset. Further analyses were conducted on the CI/CI subgroup to investigate a number of factors, such as implantation side, duration of hearing loss, amount of residual hearing, and use of HAs that may explain asymmetric performances of this subgroup.
RESULTS:: Intelligibility ranked scores in quiet and in noise were significantly greater with both CI/CI and CI/HA than with a CI-alone group, and improvement with CI/CI (+11% and +16% in quiet and in noise, respectively) was significantly better than with CI/HA (+6% and +9% in quiet and in noise, respectively). From the CI/HA group, only subjects with ranked preoperative aided speech scores >60% performed as well as CI/CI participants. Furthermore, CI/CI subjects displayed significantly lower preoperative aided speech scores on average compared with that displayed by CI/HA subjects. Routine clinical data available from the present database did not explain the asymmetrical results of bilateral implantation.
CONCLUSIONS:: This retrospective study, based on basic speech audiometry (no lateralization cues), indicates that, on average, a second CI is likely to provide slightly better postoperative speech outcome than an additional HA for people with very low preoperative performance. These results may be taken into consideration to refine surgical indications for CIs.

PMID: 25695925 [PubMed – as supplied by publisher]

Continue reading

Posted in Ear Hear | Comments Off on A Retrospective Multicenter Study Comparing Speech Perception Outcomes for Bilateral Implantation and Bimodal Rehabilitation.

Bilateral bone conduction devices: improved hearing ability in children with bilateral conductive hearing loss.

Related Articles

Bilateral bone conduction devices: improved hearing ability in children with bilateral conductive hearing loss.

Ear Hear. 2013 Nov-Dec;34(6):806-8

Authors: Dun CA, Agterberg MJ, Cremers CW, Hol MK, Snik AF

Abstract
OBJECTIVES: The aim of the study was to investigate whether children with bilateral conductive hearing loss benefit from their second device (i.e., the bilateral bone conduction device [BCD]).
DESIGN: Speech recognition in noise was assessed in 10 children fitted with bilateral BCDs during childhood. Speech recognition was measured in 2 conditions with both BCDs active. Spatial resolution was tested with the Minimum Audible Angle test in the bilateral and monaural listening conditions.
RESULTS: Children demonstrated an improvement in speech recognition when speech was presented from the front and noise was presented from the right-hand side as compared with both speech and noise being presented from the front. The minimum audible angle decreased from 57° in the best monaural condition to 13° in the bilateral condition.
CONCLUSIONS: The audiological outcomes demonstrate the advantage of bilateral BCD fitting in children with bilateral conductive hearing loss.

PMID: 23698625 [PubMed – indexed for MEDLINE]

Continue reading

Posted in Ear Hear | Tagged | Comments Off on Bilateral bone conduction devices: improved hearing ability in children with bilateral conductive hearing loss.

Audiovisual asynchrony detection and speech intelligibility in noise with moderate to severe sensorineural hearing impairment.

Audiovisual asynchrony detection and speech intelligibility in noise with moderate to severe sensorineural hearing impairment.

Ear Hear. 2011 Sep-Oct;32(5):582-92

Authors: Başkent…

Continue reading

Posted in Ear Hear | Tagged | Comments Off on Audiovisual asynchrony detection and speech intelligibility in noise with moderate to severe sensorineural hearing impairment.